Features
l Ultrasonic host operating system: Windows operating system.
l carotid artery intima measurement thickness (IMT).
l Automatic spectral envelope measurement.
l Monitor: ≥21.5 inch, high definition ultrasonic display, ≥13.3 inch touch screen.
l Applications: Abdomen, obstetrics, gynecology, heart, urinary system, small organs, superficial, blood vessels, pediatrics, newborns, musculoskeletal.
l Applications and report: Abdominal,OB,GYN,Cardiac,Urinary,Small Parts,Superficial, Vascular, Pediatrics, Advanced measurement software packages, report software packages, case management software packages, etc
Technical Specifications
PARAMETER | SPECIFICATION |
2D Imaging Mode | |
Gain | 0-100, Step 1 adjustable |
TGC | 8 segment adjustable |
Dynamic | 30-180, 35 level, step 5 adjustable |
Speckle reduction | 0-5, 5 level |
Space Synthesis | 0-2, 2 level (Liner probe: 3 level, cardiac probe:0) |
Sound power | 2-10, 9 level |
Edge Enhancement | 0-5, 5 level |
Maximum focus point | ≥7, which can be moved throughout the whole process |
Grey scale | 0-67, 67 level |
False color | 0-67, 67 level |
Image style | Soft-Comparison, 2 level |
Frame correlation | 0-4, 4 level adjustable |
Line density | low, middle, high, 3 level |
Noise reduction | 0-5, 5 level |
The screen has real-time display of voice power, probe frequency, dynamic range, pseudo color, gray scale and other 11 parameters can be adjusted. | |
Color Doppler Imaging Mode | |
Blood gain | 0-100, Step 2 |
Parameter display | Velocity, Variance |
B-Restrain (B/W restrain) | 0-7, 7 level |
Speed Through | 0-8, 8 level |
Sampling number | 6-24, 7 level |
Blood flow preferred | 0-8, 8 level |
Filtering | 1-6, 6 level |
Sound power | 2-6, 4 level |
Noise reduction | 0-4, 4 level |
Smooth treatment | 0-4, 4 level |
Frame correlation | 0-6, 6 level |
Chromatography (Blood flow graph) | 0-37, 37 level |
Line density | Low-Middle-High, 3 level |
Frequency | 4 level adjustable |
Velocity | Minimum 0.4K, Maximum 40.5K |
Convex probe | 0.4K-4.3K-38.5K |
Linear probe | 0.4K-14.7K-39.0K |
Trans-vaginal probe | 0.4K-7.8K-39.7K |
Volume probe | 0.4K-4.2K-34.8K |
Micro-convex probe | 0.4K-10.3K-40.5K |
Cardiac probe | 0.4K-7.8K-39.7K |
PS: The frequency of the probe changes and the frequency value changes | |
PS: Frame rate changes with speed | |
Pulse wave Doppler (PW) | |
Gain | 0-100, Step 2 |
Spectrum envelope function: real time automatic spectrum envelope, manual spectrum envelope, and other modes. The system automatically analyses and displays various data such as PSV, EDV, RI, PI, S/D, ACC, HR and so on. Can wake up or close. | |
Sample volume | 0.5mm- 30mm |
Blood angel | -75—75 degree, Step 5 |
False color | 0-67, 67 level |
Dynamic range | 20-40, 4 level |
Filter | 0-9, 9 level |
Smooth treatment | 1-4, 4 level |
Sound power | 2-5, 4 level |
Volume | 0-100, 10 level, Step 10 |
Audio filtering | 0-4, 4 level |
Base line | -1.0~1.0 |
Grey map | 0-67, 67 level |
Scan velocity | 100-500, 6 level |
PRF | Minimum 0.5K, Maximum 87.5K |
Convex probe | 0.5K-4.3K-63.3K |
Linear probe | 0.5K-14.5K-78.4K |
Trans-vaginal probe | 0.5K-8.1K-78.4K |
Volume probe | 0.5K-4.2K-53.8K |
Micro-convex probe | 0.5K-10.3K-81.1K |
Cardiac probe | 0.5K-4.3K-87.5K |
Frequency | 4 level |
PS: The frequency of the probe changes and the PRF value changes | |
PS: The frequency of the probe changes and the frequency value changes | |
Continuous Wave Doppler (CW) | |
Support probe | Cardiac probe |
Adjustment of B mode parameters is switchable | |
Gain | 0-100, Step 2 |
Sampling line position is adjustable | |
PRF | 0.9K~36.1K |
Baseline | -1.0~1.0 |
Blood angel | -75~75 degree |
Grey map | 0-67 |
Scan velocity | 100-300 |
False color | 0-67 |
Dynamic range | 20-40 |
Filtering | 0-9, 9 level |
Smooth treatment | 1-4 |
Frequency | 2.0MHz/2.3MHz/2.5MHz/3.0MHz, 4 level adjustable |
Sound power | 2-5 |
Volume | 0-100 |
Audio Filtering | 0-4 |
Anatomical M imaging | |
Support probe | Convex probe, Linear probe,Cardiac probe |
Adjustment of B mode parameters is switchable | |
Gain | 0-100, Step 2 |
M Sampling line angel is adjustable | |
M Sampling line length is adjustable | |
Sampling line: 3, Can be displayed or hidden separately | |
Blood flow M mode (MC) | |
Adjustment of B mode parameters is switchable | |
Gain | 0-100, Step2 |
MC Sampling line angel is adjustable | |
MC Sampling line length is adjustable | |
Frequency | 4 level |
Sampling number | 6-24 |
Speed through | 0-8, 8 level |
Scan velocity | 150-500 |
Frame correlation | 0-6, 6 level |
Filtering | 1-6, 6 level |
Blood flow preferred | 0-8, 8 level |
Smooth treatment | 0-4, 4 level |
Map | 0-37, 37 level |
Elastography | |
Adjustment of B mode parameters is switchable | |
Gain | 0-100, Step 2 |
B/E, Double real-time display on the same screen | |
Probe displacement curve display | Up/Down |
Pressure indicator bar display | |
Frequency | 8-9 level, Adjustable; According to the probe display |
Noise reduction | 0-2, 2 level |
Frame correlation | 0-3, 3 level |
Comparison | 0-13, 13 level |
False color | 0-3, 3 level |
Don’t support cardiac probe | |
Tissue Doppler imaging (TDI) | |
Support probe | Cardiac probe |
Adjustment of B mode parameters is switchable | |
Gain | 0-100, step 2 |
ROI area adjustable | |
Sampling number | 6-24 |
Velocity | 0.4K-8.0K |
Frame correlation | 0-6, 6 level |
Tissue preferred | 0-7, 7 level |
Frequency | 2.0MHz/2.3MHz/2.5MHz/3.0MHz |
Support color reversal | |
Strain rate imaging | |
Support probe | Cardiac probe |
Adjustment of B mode parameters is switchable | |
ROI area adjustable | |
Gain | 0-100, Step 2 |
Sampling number | 6-24, 6 level |
Axial average | 1-4, 4 level |
Velocity | 0.4K-8K |
Frame correlation | 0-6, 6 level |
Tissue optimization | 0-7, 7 level |
Panoramic imaging | |
Support probe | Linear probe |
Speckle Reduction | 0-5, 5 level |
Deflection imaging | |
Support probe | Linear probe |
Adjustment of B mode parameters is switchable | |
Deflection angel | 8 level |
Speckle reduction | 0-5, 5 level |
Dynamic rate | 30-180, Step 5 |
Line density | low-middle-high, 3 level |
Frame Correlation | 0-4, 4 level |
False color | 0-67, 67 level |
Image style | Soft-Comparison, 2 level |
Noise reduction | 0-5, 5 level |
Edge Enhancement | 0-5, 5 level |
Sound power | 2-10, 8 level |
Grey map | 0-67, 67 level |
Trapezoidal imaging | |
Probe support | linear probe |
Adjustment of B mode parameters is switchable | |
Deflection angel | 8 level |
Speckle reduction | 0-5, 5 level |
Dynamic rate | 30-180, Step 5 |
Line density | low-middle-high, 3 level |
Frame Correlation | 0-4, 4 level |
False color | 0-67, 67 level |
Image style | Soft-Comparison, 2 level |
Noise reduction | 0-5, 5 level |
Edge Enhancement | 0-5, 5 level |
Sound power | 2-10, 8 level |
Grey map | 0-67, 67 level |
Space Synthesis | 0-2, 2 level |
Freehand 3D imaging | |
Support probe | convex probe, linear probe |
Display model | 4 pictures |
Image Rotation X/Y/Z Axis | |
Multi-slice Visibility | |
Real-time 4D imaging | |
Support probe | 4D volume probe |
Adjustment of B mode parameters is switchable | |
Gain | 0-100, Step 2 |
Display model | one image, two images, four images |
Image Rotation: X/Y/Z Axis | |
Multi-slice Visibility | |
Light&Shade inversion | |
Smooth | 0-4, 4 level |
Threshold level | 0-129, Step 3 |
Transparency | 1-509, Step 10 |
Render type | 4 kinds, Surface, maximum, minimum, perspective |
Extended Imaging | |
Gain | 0-100, Step 2 |
TGC | 8 segment adjustable |
Maximum focus point | ≥7, which can be moved throughout the whole process |
Speckle reduction | 0-5, 5 level |
Space Compound | 0-2, 2 level (Linear probe: 3 level, don’t support cardiac probe) |
Dynamic range | 30-180, 35 level, Step 5 |
Line density | Low, Middle, High, 3 level |
Frame correlation | 0-4, 4 level |
Noise reduction | 0-5, 5 level |
Edge enhancement | 0-5, 5 level |
Sound power | 2-10, 9 level |
Grey map | 0-67, 67 level |
False color | 0-67, 67 level |
Image style | Soft-Comparison, 2 level |
Extended level | Maximum 72 level |
Convex probe | 9 level |
Trans-vaginal probe | 72 level |
Micro-convex probe | 29 level |
Cardiac probe | 40 level |
4D Volume probe | 17 level |
PS: The screen has real-time display of voice power, probe frequency, dynamic range, pseudo color, grayscale and other 11 parameters can be adjusted | |
PS: When the probe scan range reaches the maximum, the space synthesized is 0. |
Various Probes
l Convex probe
Fundamental Frequency: 2.0MHz/ 2.3MHz/ 2.5MHz/ 3.0MHz/ 3.5MHz/ 4.0MHz/ 4.6MHz/ 5.0MHz/ 5.4MHz
Harmonic Frequency: 4.0MHz/ 4.6MHz/ 5.0MHz
l Linear probe
Fundamental Frequency: 4.0MHz/ 4.6MHz/ 5.0MHz/ 6.0MHz/ 7.0MHz/ 8.0MHz/ 9.2MHz/ 10.0MHz/ 12.0MHz/ 13.3MHz
Harmonic Frequency: 8.0MHz/ 9.2MHz/ 10.0MHz
l Micro-convex probe
Fundamental Frequency: 3.0MHz/ 3.5MHz/ 4.0MHz/ 5.0MHz/ 5.4MHz/ 6.0MHz/ 7.0MHz/ 8.0MHz
Harmonic Frequency: 6.0MHz/ 7.0MHz/ 8.0MHz
l Cardiac probe
Fundamental Frequency: 1.7MHz/ 1.9MHz/ 2.1MHz/ 2.5MHz/ 3.0MHz/ 3.4MHz/ 3.8MHz/ 4.2MHz/ 5.0MHz
Harmonic Frequency: 3.4MHz/ 3.8MHz/ 4.2MHz
l 4D volume probe
Fundamental Frequency: 2.0MHz/ 2.5MHz/ 3.0MHz/ 3.3MHz/ 3.7MHz/ 4.0MHz/ 5.0MHz/ 6.0MHz
Harmonic Frequency: 4.0MHz/ 5.0MHz/ 6.0MHz
l Rectal linear probe
Fundamental Frequency: 4.0MHz/ 4.6MHz/ 5.0MHz/ 6.0MHz/ 7.0MHz/ 8.0MHz/ 9.2MHz/ 10.0MHz/ 12.0MHz/ 13.3MHz
Harmonic Frequency: 8.0MHz/ 9.2MHz/ 10.0MHz
Graphic and Text Management System
l Host build in 2 hard disk (SSD 120+1T), start fast and stable.
l Movie playback: ≥1200 frames.
l Type of report is 16.
l One key fast report graphic and text management.
l Internal file information management system: can record patient number, name, check number, check date and so on, and can be searched and managed by numbering, checking number, name and so on.
Contact: Mr.Shao
Phone: 86-19805651775
E-mail: sales@hqs-vetcare.com / info@hqs-vetcare.com
Whatsapp:86-19805651775 / 81-08068730425
Add: Room 402, Unit 6, Building 27, Pingchou District 2, Jiangdong Street, Yiwu, Jinhua, Zhejiang Province
WhatsApp Chat