Welcome: HQS VETCARE

H902-C Anesthesia Machine

Features                     

1.      No electricity will be needed, only manual operation

2.      Module rack with polyester medical material, high strength and light weight.

3.      Superior thin spray technology, delicate color, beautiful and durable.

4.      High precious vaporizer, Halothane, Enflurane, Isoflurane and Sevoflurane could be choosen freely

5.      Main unit are only 2Kg (w/o vaporizer), light weight and easy to move

6.      With a dedicated handle, could move by hand-pull.

7.      Two gas sources: O2, N2O, suitable for more patient type

8.      Classical CO2 circle absorber with 1 canister, low resistance, minimum gas leakage, 60cmH2O peak pressure solution.

9.      Ventilator (Optional): TH-1, TH-1A

10.  3 types of Small Vaporizers and 4 types of Big Vaporizers for choice.

 

Technical Specifications

PARAMETER

SPECIFICATION

Ventilation mode

Closed, Semi-closed, Semi-open

Application

2-100KG animals

Gas source

O2, N2O     0.25Mpa~0.65Mpa

Two tube (O2, N2O)

Scope,0—10L/min.With linkage device,O2   concentration not low than 25%

O2 flush

more than 25L/min

Respiratory mode

Manual, Oxygen

TV

50~2000mL

I:E

according to the doctor operation

BPM

according to the doctor operation

APL Valve pressure

0.5-6KPa

Monitoring

Airway pressure, respiratory mode

Three Gauges

one for O2, one for N2O, one for airway pressure  

Environment Requirement

Temperature

Operation: 18~36 ºC

Storage: -20~55 ºC

Humidifier

Operation:45%~75%

Storage:≤93%

Atmospheric pressure

Operation:0.95~1.05 bar

Storage: 500hPa~1060hPa

Altitude

Operation:500 to 800mmHg (3565~-440m)

Storage:375 to 800mmHg (5860~-440m)

 

Two Anesthesia Ventilators (Optional)

- Independent Anesthesia Ventilator, with IPPV and Manual mode

- With necessary monitoring and alarm function, to make sure the operation safety

- Gas supply: O2, or Air

- With international connector, can be matched with various brands of anesthesia machines

 

TH-1A Parameter

- Respiration mode: IPPV, SIMV, Manual

- Respiratory frequency: 1 to 65BPM

- Display: 5.5´ SNT screen

- I:E ratio: 8:1~1:8

- Waveform: P-t, V-t

- Tidal volume: 50ml~1600ml

- Monitor Parameters: Tidal volume; Minute Ventilation; Peak

 

TH-1 Parameter

- Control method: Gas driving electronic controlled

- Breath frequency: 1~90BPM

- Display: High light LED display

- I:E ratio: 4:1~1:6

- Respiration mode: IPPV, Manual

- Tidal volume: 50~1500ml

- Monitor Parameters: Tidal volume; Minute Ventilation; Breath Frequency; Airway Pressure


CATEGORIES

CONTACT US

Contact: Mr.Shao

Phone: 86-19805651775

E-mail: sales@hqs-vetcare.com / info@hqs-vetcare.com

Whatsapp:86-19805651775 / 81-08068730425

Add: Room 402, Unit 6, Building 27, Pingchou District 2, Jiangdong Street, Yiwu, Jinhua, Zhejiang Province