Features
1. No electricity will be needed, only manual operation
2. Module rack with polyester medical material, high strength and light weight.
3. Superior thin spray technology, delicate color, beautiful and durable.
4. High precious vaporizer, Halothane, Enflurane, Isoflurane and Sevoflurane could be choosen freely
5. Main unit are only 2Kg (w/o vaporizer), light weight and easy to move
6. With a dedicated handle, could move by hand-pull.
7. Two gas sources: O2, N2O, suitable for more patient type
8. Classical CO2 circle absorber with 1 canister, low resistance, minimum gas leakage, 60cmH2O peak pressure solution.
9. Ventilator (Optional): TH-1, TH-1A
10. 3 types of Small Vaporizers and 4 types of Big Vaporizers for choice.
Technical Specifications
PARAMETER | SPECIFICATION |
Ventilation mode | Closed, Semi-closed, Semi-open |
Application | 2-100KG animals |
Gas source | O2, N2O 0.25Mpa~0.65Mpa |
Two tube (O2, N2O) | Scope,0—10L/min.With linkage device,O2 concentration not low than 25% |
O2 flush | more than 25L/min |
Respiratory mode | Manual, Oxygen |
TV | 50~2000mL |
I:E | according to the doctor operation |
BPM | according to the doctor operation |
APL Valve pressure | 0.5-6KPa |
Monitoring | Airway pressure, respiratory mode |
Three Gauges | one for O2, one for N2O, one for airway pressure |
Environment Requirement | |
Temperature | Operation: 18~36 ºC |
Storage: -20~55 ºC | |
Humidifier | Operation:45%~75% |
Storage:≤93% | |
Atmospheric pressure | Operation:0.95~1.05 bar |
Storage: 500hPa~1060hPa | |
Altitude | Operation:500 to 800mmHg (3565~-440m) |
Storage:375 to 800mmHg (5860~-440m) |
Two Anesthesia Ventilators (Optional)
- Independent Anesthesia Ventilator, with IPPV and Manual mode
- With necessary monitoring and alarm function, to make sure the operation safety
- Gas supply: O2, or Air
- With international connector, can be matched with various brands of anesthesia machines
TH-1A Parameter
- Respiration mode: IPPV, SIMV, Manual
- Respiratory frequency: 1 to 65BPM
- Display: 5.5´ SNT screen
- I:E ratio: 8:1~1:8
- Waveform: P-t, V-t
- Tidal volume: 50ml~1600ml
- Monitor Parameters: Tidal volume; Minute Ventilation; Peak
TH-1 Parameter
- Control method: Gas driving electronic controlled
- Breath frequency: 1~90BPM
- Display: High light LED display
- I:E ratio: 4:1~1:6
- Respiration mode: IPPV, Manual
- Tidal volume: 50~1500ml
- Monitor Parameters: Tidal volume; Minute Ventilation; Breath Frequency; Airway Pressure
Contact: Mr.Shao
Phone: 86-19805651775
E-mail: sales@hqs-vetcare.com / info@hqs-vetcare.com
Whatsapp:86-19805651775 / 81-08068730425
Add: Room 402, Unit 6, Building 27, Pingchou District 2, Jiangdong Street, Yiwu, Jinhua, Zhejiang Province
WhatsApp Chat