Part 1- Video Processor and Light Cold Source 2 in 1 Machine (Full HD 1080P)
PARAMETER | SPECIFICATION |
Lamp | LED light (100W white) |
Power | 100-240V; 50-60HZ |
Illuminance | ≥3,000,000 lux |
Color temperature | ≥5700K |
Video signal output | CVBS ,HD-SDI , VGA , DVI-D,HDMI |
Brightness adjustment | 0-100 grade |
Withe balance | One-click white balance |
Main Function | Support one -click freeze single image With 5 Inch color LCD high sensitive touch screencontral board |
Part 2- Electrosurgical Unit
PARAMETER | SPECIFICATION |
Power supply | 110/220V ~ 50/60HZ |
Power capacity | 1100VA |
Classify | Class I Type BF |
Working mode | Intermittent loading, working continuously |
Fuse | BGXP5×20 5A 3pcs |
Highest frequency | 400W 500Ω |
Packing | Handle with care, upward, keep dry etc. |
Machine power dissipation | ≤1000VA (CUT 400W, BIOPOLAR 70W output) |
Barometric pressure | 500hPa~1060hPa |
Temperature | 5℃~40℃ |
Relative humidity | ≤80 |
Barometric pressure | 86.0~106.0kPa |
Working frequency | 360~512kHz |
Part 3- CO2 Pneumoperitoneum Insufflator Machine
PARAMETER | SPECIFICATION |
Power supply voltage | AC220V |
Power frequency | 50Hz |
Input power | 40VA |
Fuse | 1A |
Control range of gas injection pressure | 0.67kpa ~ 3.30kpa (1mmhg) |
Control accuracy of gas injection pressure | ± 0.13kpa (1mmhg) |
Flow rate range of injected gas | 1L / min - 30L / min respectively |
Allowable deviation of injected gas flow rate | ±20% |
Part 4- Souice Pump
PARAMETER | SPECIFICATION |
Voltage | AC220V 50HZ |
Rated Pwr. | 50VA |
Range of the pos-pressure | 10~50kPa |
Range of the neg-pressure | -50~-10 kPa |
Safe classification | Type I Model B |
Run mode | Inter loading/Cont. Duty |
Noise | ≤50dB |
Part 5- Irrigation Pump
PARAMETER | SPECIFICATION |
Voltage | 240v,50Hz/60Hz |
Rated Pwr. | 100VA |
Range of the Press. | 15~400mmHg (2~53.3kPa) |
Range of flw. | 0.1~1.0 L/min |
Safe classification | Type I Model B |
Run mode | Inter loading/Cont. Duty |
Noise | ≤50dB |
Host size | 360*315*160mm/ 9KGS |
Part 6- LCD Monitor
PARAMETER | SPECIFICATION |
Display size | 24” |
Power Supply | External Power Supply 24V |
Resolution | 1920x1200 |
Display Ratio | 16:10 |
Color | 1.07B |
Camoration Brightness | 180±10 cd/㎡ |
Max.Brightness | 400 cd/㎡ |
Package size | 65*36.5*60cm (G.W.:16.0kgs) |
Part 7- Equipment Vehicles
PARAMETER | SPECIFICATION |
Size | 500 * 700 *1350mm |
Package size | 118.5*63.5*22cm (G.W.:28kgs) |
Part 8- Sterilization Equipment
PARAMETER | SPECIFICATION |
Indoor volume | Φ400X625mm |
Size | 522X567X1020mm |
Automatic pressure sterilization equipment | |
Size | 785X 575X1800mm |
Storage Volume | 5/6 layers |
Voltage power supply | 12V 50Hz 30W |
Sterilization mode | Manual automatic |
Main functions | It can display the date, time, week and cumulative desinfection time, temperature and humidity, circulation wind drying, ulraviolet ray, ozone disinfection, Biopsy forceps hook, and lighting LED lamp in open cabinet. |
Rigid endoscope Part
CJ-1 Sigmoidoscopy set
ITEM | NAME | SPECIFICATION |
H1001 | Sigmoidoscope | Ф20×300,fiber inside |
H1002 | Sigmoidoscope | Ф15×300,fiber inside |
H1003 | Sigmoidoscope | Ф20×230,fiber inside |
H2001 | Biopsy forceps | Straight 380mm |
H2002 | Biopsy forceps | Left curved 380mm |
H2003 | Biopsy forceps | Right curved 380mm |
H2004 | Biopsy forceps | Dissecting 350mm |
H2005 | Cotton applicator | 350mm |
H2006 | Hand insufflator | With tube |
H0001 | Microscope | Φ1X340mm |
T5010 | Light guide cable | Ф4.5×2000mm |
CJ-3 Sigmoidoscopy set
ITEM | NAME | SPECIFICATION |
A0011 | Endoscope | 12°, Ф4mm |
H1004 | Sigmoidoscope | Ф20×267, fiber inside |
H1005 | Manipulator | Ф17×279mm |
F2101 | Biopsy forceps | Flexible |
H2002 | Biopsy forceps | Left curved 380mm |
H2003 | Biopsy forceps | Right curved 380mm |
H2004 | Biopsy forceps | Dissecting 350mm |
H2005 | Cotton applicator | 350mm |
H2006 | Hand insufflator | |
T5010 | Light guide cable | Ф4.5×2000mm |
Laparoscopy
NAME | SIZE | QTY/UNIT | PICTURE |
Light guiding line | Φ4×2500mm | 1/pc | |
Insufflator needle | 100-150mm | 1/pc | |
Electric Ballpoint | Φ5×330mm | 1/pc | |
Sealing cap | Φ5mm | 10/pc | |
Curved dissectig forceps | Φ5×330mm | 1/pc | |
Curved scissors forceps | Φ5×330mm | 1/pc | |
Electrode hook | Φ5×330mm | 1/pc | |
Torcars | Φ5mm | 1/pc | |
Flap valve spiral trocar | Φ10mm | 2/pc | |
Tissue biopsy forceps | Φ5×330mm | 1/pc | |
Clip applicar | Φ5×330 | 1/pc | |
Titanium clip | 1/box | ||
Laparoscopy | Φ10mm/0° | 1/pc |
Optional accessories
NAME | SIZE | QTY/UNIT | PICTURE |
Atraumatic grasping forceps | Φ5×330mm | 1/pc | |
Dissecting forceps 90° | Φ5×330mm | 1/pc | |
Surgical forceps 90° | Φ5×330mm | 1/pc | |
Needle -holding forceps | Φ5×330mm | 1/pc | |
Knotter forceps | Φ5×330mm | 1/pc | |
Intestine forceps | Φ5×330mm | 1/pc | |
Salpinx grasping forceps | Φ5×330mm | 1/pc | |
Trefoil expansion forceps | Φ5×330mm | 1/pc | |
Spatula- electrode | Φ5×330mm | 1/pc | |
Kont-pusher | Φ5×330mm | 1/pc | |
Bipolar forceps | Φ5×330mm | 1/pc | |
Bipolar scissors | Φ5×330mm | 1/box | |
Flushing tube | Φ5×330mm | 1/pc | |
Flusher | 1/pc | ||
adaptor | 10mm-5mm | 1/pc | |
Titanium clip | L | 1/box | |
Titanium clip | M | 1/box | |
Trocars | 10mm | 1/pc | |
Flap valve spiral trocar | 10mm | 1/pc | |
Sealing cap | 10mm | 10/pc | |
Clean brush | 10X480mm | 1/pc | |
Clean brush | 5X 480mm | 1/pc |
Sinoscope
NAME | SIZE | QTY/UNIT | PICTURE |
Sinoscope /Rhinoscope | Φ3×170, 0° | 1/pc | |
Polypus froceps | Φ3×95, 100° | 1/pc | |
Polypus froceps | Φ3×85, 70° | 1/pc | |
Polypus froceps | Φ3×85, 70° | 1/pc | |
Polyp Nasal froceps | Φ4×148 | 1/pc | |
Nasal Scissore | Φ4×125, Left bending | 1/pc | |
Nasal Scissore | Φ4×125, Right bending | 1/pc | |
Nasal Scissore | Φ4×125 | 1/pc | |
Optics forceps | Φ4×125, 0° | 1/pc | |
Sinus rongeur | Φ4×125 | 1/pc | |
Nasal ethmoid forceps | Φ4×125, 90° | 1/pc | |
Nasal ethmoid forceps | Φ4×125, M | 1/pc | |
Nasal ethmoid forceps | Φ4×125, L | 1/pc | |
Nasal ethmoid forceps | Φ4×125, 30° | 1/pc | |
Nasal ethmoid forceps | Φ4×125, Up 90° | 1/pc | |
Sinus rongeur | Φ4×125, Front biting | 1/pc | |
Nasal ethmoid forceps | Φ4×125, 45° | 1/pc | |
Sinus rongeur | Φ4×125 | 1/pc | |
Nasal sinus forceps with suction tube | Φ4×95 | 1/pc | |
Sinus rongeur | Φ4×110 | 1/pc | |
Sinus rongeur | Φ3×6×150 | 1/pc | |
Trocar | Φ4×100 | 1/pc | |
sickie-shaped knife | Φ1.8×170 | 1/pc | |
sickie-shaped knife | Φ1.8×170 | 1/pc | |
suction catheter | Φ3.6×175 | 1/pc | |
suction catheter | Φ3×175 | 1/pc | |
suction catheter | Φ2.5×175 | 1/pc | |
suction catheter | Φ2.5×110 | 1/pc | |
antrum curette | 80mm | 1/pc | |
antrum curette | 80mm | 1/pc | |
Detacher | 80mm | 1/pc | |
Endoscope proctection cover | 3/pc |
Rigid Cystoscope parts
NAME | SIZE | QTY/UNIT | PICTURE |
Cystoscopy | φ4*300mm /0° | 1/pc | |
Sheath and adaptor | F19.5×230 | 1/pc | |
Flexible biopsy forceps | φ2.3×400 | 1/pc | |
Flexible grasping forceps | φ2.3×400 | 1/pc | |
Flexible biopsy forceps | φ2.3×400 | 1/pc | |
Flexible scissors | φ2.3×400 | 1/pc | |
Single intubation endoscope bridge | 1/pc | ||
Inlet valve | 1/pc | ||
Outlet valve | 1/pc | ||
Irrigation tube | 1/pc | ||
Sealing cap | 1/pc | ||
Flap valve spiral trocar | Φ5mm | 2/pc |
Arthroscopy Part
NAME | SIZE | QTY | UNIT | |
Endoscope | 0°Ф4×175mm, wide angle | 1 | Pc | |
Endoscope | 30°Ф4×175mm, wide angle | 1 | Pc | |
Endoscope | 70°Ф4×175mm, wide angle | 1 | Pc | |
Hooked scissors | 0° straight | 1 | Pc | |
Hooked scissors | 15° upward | 1 | Pc | |
Hooked scissors | 30° left curved | 1 | Pc | |
Hooked scissors | 15°downward | 1 | Pc | |
Hooked scissors | 30° right curved | 1 | Pc | |
Punch forceps | 0° straight | 1 | Pc | |
Punch forceps | 15° upward | 1 | Pc | |
Punch forceps | 30° left curved | 1 | Pc | |
Punch forceps | 15°downward | 1 | Pc | |
Punch forceps | 30° right curved | 1 | Pc | |
Grasping forceps with tooth | 0° straight | 1 | Pc | |
Banana-shaped knife | 92mm | 1 | Pc | |
Rose-shaped knife | 92mm | 1 | Pc | |
Rasp | 92mm | 1 | Pc | |
Meniscotome | 92mm | 1 | Pc | |
Probe | 3×92mm/ 4×92mm | 1 | Pc | |
Ligamentous cutting knife | 1 | Pc | ||
Hooked knife | 7×92mm | 3 | Pc | |
Curette | 5×92mm, with hole | 1 | Pc | |
Curette | 7×92mm cup shaped | 2 | Pc | |
Knife | 45° contra-angled | 2 | Pc | |
Trocar set | Ф5×140mm | 1 | Pc | |
Trocar set | Ф4×140mm | 1 | Pc | |
Adaptor | 1 | Pc | ||
Suction tube | Ф4×155mm | 1 | Pc | |
Suction tube | Ф3×155mm | 1 | Pc | |
Suction tube | Ф2.5×155mm | 1 | Pc | |
Contact: Mr.Shao
Phone: 86-19805651775
E-mail: sales@hqs-vetcare.com / info@hqs-vetcare.com
Whatsapp:86-19805651775 / 81-08068730425
Add: Room 402, Unit 6, Building 27, Pingchou District 2, Jiangdong Street, Yiwu, Jinhua, Zhejiang Province